Company profile
   Companies Represented
   Projects
   News
   Tools
   Contact Us
 
                          |   VSWR Tools  |   Free Space Loss  |   Power Conversion  |   Antenna Spacing  |  
 

Conversions of power levels between W, dBW and dBm

 

Conversions of power levels between W, dBW and dBm
P = 10 log_10 (p/p_0)                 p_0, dBW = 1 W ; p_0, dBm = 1 mW

P = 
dBW
Power :  
P = 
dBm

p = 
W

Enter one value (either in dBW, dBm or W) and click the "Convert" button next to it to compute the two other values.


Conversions of amplitude levels between V, dBV and dBuV
U = 20 log_10 (u/u_0)                 u_0, dBV = 1 V ; u_0, dBuV = 1 uV

U = 
dBV
Amplitude :  
U = 
dBuV

u = 
V

Enter one value (either in dBV, dBuV or V) and click the "Convert" button next to it to compute the two other values.


Conversions between dBuV and dBm

P = 10 log_10 (p/p_0)                 p_0 = 1 mW
U = 20 log_10 (u/u_0)                 u_0 = 1 uV
p = u^2 / Z_c
Impedance :  
Zc = 
Ohm
Power :  
P = 
dBm
Amplitude :  
U = 
dBuV


Enter the impedance in Ohm and one value (either the power in dBm or the amplitude in dBuV) and click the "Convert" button next to it to compute the other value.

This conversion is only valid when the impedance Zc is real and the load is matched to the transmission line.
 